Heat Pipe Solar Collector
1. Super Type Heat pipe
2. Beautiful design
3. Good quality
4. Competitive price
Heat Pipe Solar Collector
Sytle NO. GSSC-064 Heat Pipe Hot Water Solar Collector System
Model
GSSC-064
Type
Evacuated tube collector
No. Of tubes
PCS
12
18
20
24
Spec. of tube
mm
φ58×1800
Gross length
mm
1970
Gross width
mm
1023
1473
1623
1923
Gross height
mm
135
Gross area
m2
2.015
2.901
3.197
3.788
Aperture area
m2
1.230
1.847
2.051
2.46
Absorber area
m2
0.99
1.47
1.634
1.961
Weight
Kg
45
68
71
93
Header/heat pipe
Red copper (TU1)
Tube material
Borosilicate glass 3.3
Coating of tube
Al-N/Al-Cu
Interval of tube
mm
75
Outer diameter header pipe
mm
22mm
Inner diameter header pipe
mm
20mm
Manifold casing material
Aluminum alloy
Sealing material
EPDM
Frame material
Aluminum alloy
Operating pressure
MPa
0.6
Loading QTY 20'/40' GP
set
124/250
90/188
83/174
72/148
Notice:
1.Installation must be completed in accordance with the relevant local standards and regulations.
2. Installation must be completed by qualified plumbing professionals.
3. Before installation, please check the collectors first. If the bottom of tube is silver, the tube is good. If a tube has a white or clear bottom, it is damaged and should be replaced. Please exchange them this way: Unfasten and remove the plasic cap on the bottom, then pull the broken tubes out along with the direction of the collector, then replace a good tube and install the cap. Please do not to damage the copper heat pipes inside the glass tubes.
4. Do not expose the tubes to sunlight, otherwise the inner tube and heat transfer fin will become very hot. The outer glass surface will not become hot. Avoid exposing the collector to sunlight until the liquids are inside the manifold.
5. If two or more collector units are used on the roof, please use connectors to connect the collectors, so that the connecting is durable and solid, without any leakage of water.
6. Manifold is not significantly shaded throughout the day.
7. Manifold is not likely to be struck by failing objects such as branches, falling fruit, or other objects.
8. Collector is installed at an angle of between 20° -70° , preferable at laatitude angel.
9. In areas prone to large hail(>20mm), collector is installed at an angel of 40 ° Or greater.
10. Frame is secured to structurally sound roof framing
11. Plumbing is leak free
12. Insulation above roof level is protected with foil wrap or equivalent.
13. Controller is configured correctly with freeze setting on
14. PTRV will dump only onto high temperature resistant materail and will not pose a danger of scolding people.
15. Pump, controller and all electrical connections are protected from water ingress
16. Evacuated tubes have been cleaned.
17. Functuinal checks for controller and pump have been completed.
18. Water quality has been checked.
19. Water in direct flow through the manifold header must meet potable water requirements
No comments: