Friday, July 15, 2011

PV Wire(UL)

UL PV WIRE
Specifically designed for connecting photovoltaic system components inside and outside of building and equipment.

UL pv wire and cable use the advanced E-beam cross-linked processing technology. The wire with the low smoke and halogen free flame retardant material has many advantage such as high temperature resistance , anti-ozone, anti-ultraviolet, anti-water vapour, anti-microbiology, strong short-term overload ability.
1.Rating: Voltage: 600/1000V Temperature: -40°C-- 90°C
2. Description: (1)Conductor: Tinned annealed copper
(2)Insulation: 90°C XLPE , black
(3)Jacket: 90°C XLPE , black or white
3.Marking: E332231 (UL) Type PV Wire **AWG 90°C Dry and Wet 600V Sun Res -40°C VW-1 HZSF

4.Construction:
Conductor
Insulation
Insulation Standard Dia.
Jacket
Outer Dia.
Conductor resistance (20°C)
Max. Current Carrying Capacity
Type
Construction
Conductor Dia.
Standard Thickness
Standard Thickness
AWG
N/mm
(about)mm
mm
mm
mm
mm
Ω/km
Amp
10 AWG
65/0.32±0.006
2.97
1.23
5.43±0.1
0.80
7.03±0.2
3.55
62
12 AWG
65/0.254±0.006
2.36
1.22
4.80±0.1
0.80
6.40±0.2
5.64
42
14 AWG
41/0.254±0.006
1.89
1.20
4.29±0.1
0.80
5.89±0.2
8.96
25
16 AWG
26/0.254±0.006
1.49
1.20
3.89±0.1
0.80
5.49±0.2
14.6
15
Approvals:UL design tested, certificate No E 332231
5. Electrical Properties:
Item
Units
Specification
Conductor resistance(20°C)
Ω/km

Insulation resistance(90°C)
Ω/cm
≥10¹¹
Withstand voltage
V/5min
AC6500
Lifetime
year
≥25years
Min. Bending Radius

5D