Tuesday, May 10, 2011

Solar-Mains Complementary Intelligent Controller (Direct Current type)

1.using professional control solutions
2.with excellent performance and reliable quality
3.switching to direct current power
Design Features:
1. The function of automatic switcher of mains: when the storage battery is under voltage, the load power supply will switch to the electric supply.
2. Under the situation of the storage battery becoming valid or stolen, the system can test automatically and the mains will supply the power to the load to make it work normally.
3. Two options of trig mode for the users:
A. Mains trig mode: as electric supply got through, the load begins to work (Ensuring the load to turned on simultaneously).
B. Light-control trig mode.
4. Professional charging and discharging circuit and intelligent control for the whole system.
5. Based on spare capacity of storage and the discharging protected mode of battery voltage.
6. Clear and readable display for all kinds of operating state.
7. Having the function of preventing surging, short circuit, reverse connection, overload and so on.
Technical Parameters:
Type
MYSMC-L105DY
MYSMC-L110DY
MYSMC-L115DY
MYSMC-L120DY
Rated Charging Current
5A
10A
15A
20A
Rated Load Current
5A
10A
15A
20A
Short Circuit Protection Current
10A
15A
18A
25A
Overload Protection
5A/20s
10A/20s
15A/20s
20A/20s
System Voltage
24V/12V
Contour Dimension
(mm)
240(L)×120(W)×85(H)
No-load Loss
≤30mA
Discharge Circuit Voltage Drop
≤2% (Note: Not including wire loss)
Working Temperature
From -25°C to +55°C
Full of Voltage
29V ±0.4V/14.5±0.2V (Corresponding adjustment according to
the customers’ actual situation)
Overpressure Voltage
30V ±0.5V/15.0±0.5V (Corresponding adjustment according to
the customers’ actual situation)
Ultrahigh Voltage
Protection
33V±1V
The Low Battery Voltage Instructions
24V/12V
Discharge Voltage (Under voltage) /
The Storage Battery Voltage of
Commercial Power Supplying Power
22 V±0.4V / 11.1±0.2V
(Corresponding adjustment according to
the customers’ actual situation)
Discharge Return Voltage
/ Power Restoration Voltage
of the Storage Battery
25.6V±0.4V / 12.6 ±0.2V
(Corresponding adjustment according to
the customers’ actual situation)
Load Control Mode
Commercial Power Trigger/Light-control Trigger
Light-controlled Cut-in
Voltage
2V±0.5V/4V±1V
Light Controlled Power
On and Off Delayed
2~5
The Switch Time of
Commercial Power
≤250ms
Commercial Power
220Vac±20% 50Hz
Resetting
Press the reset button for a long time>15s
Weight
1kg
Diameter of the Installed Wire
0.5mm2—6mm2 (22—9AWG)
Protection Grade
IP52