Tuesday, August 16, 2011

12v/24v PWM solar charger controller ZYTK01

PWM solar charger controller
1.program timer,intelligent
2.recognized 12v/24v
3.intelligent controller
4.waterproof
PWM solar charger/intelligent controller

Instruction

The model comes with high water-repellent/waterproof function.
The sollar intelligent controller is for off-grid solar system and control the charging and discharging of the battery. The controller features a smart tracking algorithm inside that maximizes the energy from the solar PV module(s) and charge the battery. At the same time, the low voltage disconnect function (LVD) will prevent the battery damage from battery over discharging.
Furthermore the comprehensive self-diagnostics and electronic protection functions can prevent damage from installation mistakes or system faults,such as overload,shoring,reverse connection.
Particularly the solar controller can work effectively under water 2 meters.

Features:

1.program timer
2.recognized 12v/24v,temprature compensate
3.solar charge controller,intelligent controller
4.working mode:light controller,light controller+timer,manu
5.current capacity:10A
6.working voltage:12v/24v auto recognized
7.consumer power<12VA
8.time range:1-24h
9.protection class:IP68
10.max load current:10A/double 5AX2
11.auto prevent from overload,shorting,reverse connection
9.LED display

Model
ZYTK01
ZYTK01
Working voltage
DC12V/DC24V identify automatically
Bitmap
DC12V/DC24V identify automatically
Rated charge/discharge current
10A,10AX2;5A/circle,10A
12A or customized
System voltage
12V;24V;12V/24V Auto
12V;24V;12V/24V Auto
No-load currrent
<12mA
<12mA
Overvoltage protection
16V/32V
16V/32V
temprature compensating
-3.9mV/B8/2V
-3.9mV/B8/2V
control method
charge:PWM
charge:PWM
working temprature
-10~+55°C
-10~+55°C
storage temprature
-20~+70°C
-20~+70°C
overloa,shorting protection
cut off output 3s later when testing 1.25 times of rated current;cut off output immediately when testing 1.5 times of Rated current
cut off output 3s later when testing 1.25 times of rated current;cut off output immediately when testing 1.5 times of Rated current
recovery voltage of charging
13.6V/27.2V
13.6V/27.2V
recovery voltage of loading
12.6V/25.2V
12.6V/25.2V
back coverage of charging
13.2V/26.4V
13.2V/26.4V
discharging back voltage
13.2V/26.4V
13.2V/26.4V
over-discharge back voltage
12.6V/25.2V
12.6V/25.2V
under voltage
12.0V/24V
12.0V/24V
Over-discharge voltage
11.0V/22V
11.0V/22V