1.Solar collector with Solar Keymark
2.Simple installation and mounting
3.Compatible with existing filtration systems
1. Working principle of high pressure solar heater: Utilizes the alternative
Absorption coating on the inner surface of the vacuum tube, from the High-temperature environment super conduction tubes, leads the heat to the water tank, and produces hot water
2. Easy to use, also convenient to install
3. Can be put in the courtyard, on the roof or balcony
4. Inlet water hole connects to the tap water, and the outlet hole connects
To the tap water, and the outlet hole produces pressure hot water directly
5. Working principle of low pressure solar heater: Adopts the alternative
Absorption coating to absorb the solar energy, heat the water in the vacuum tube directly, through the cold hot water convection, changes the solar energy into heat energy to store in the water tank:
A) Adopts the double-deck highly special hard glass tube of boron silicon
B) Double-deck glass coaxial structure, intermediate layer releases the
Vacuum, maintains 5 x 10-2Pa high vacuum for a long time while in
Charge
C) Magnetism accuse of alternative absorption coating, AL / N / AL of
Sputter aluminum nitrogen aluminum alternative absorption coating
Solar radiation absorption rate ≥ 93%, and hot emittance ≤ 6%
D) Long performance life: 15 years
E) Endures climate feature: Thermal efficiency is good in the whole year
Solar thermal collector specifications:
1. Water tank (interior): Stainless steel
2. Water tank (exterior): PVDF
3. Glass tube dimensions: 58mm x 1.8m / 47mm x 1.5m
4. Heat preservation: 72hrs
5. Hail resistance: 25mm
Technical Data of Heat pipe collector
Production Model
FD-58
FD-58
Numbers of tube(pcs)
30
20
Absorber area approx.(m2)
2.439
1.626
Gross size(m)
1.99*2.1*0.154
1.99*1.4*0.154
Weight Empty(kg)
93.5
63
Hydraulic Connections
G3/4" male thread
Loading qty in 20 GP/40GP/40HQ
63/130/145
90/185/210
Fluid volume(L)
1.7
1.2
Min. volume flowrate per collector(L/H)
108
72
Rated volume flowrate per coll.(L/H)
180
120
Max. volume flowrate per collector(L/H)
1200
1200
Maximum operation pressure(Bar)
6
Test pressure(Bar)
9
Heat transfer fluid
Anti-freeze Fluid (Water-Glycol)
Max.working temp.
250C
hot water(L/Day)
240C
160
ΔT
35C(Radiation>=800w/m2.day)
Collector efficiency
76.4% 76.2%
Medium
Pure water
Start-up Temperature of heat pipe
<=30C
warranty
5 years
Mateial Details
Produciton Model
FD-58
Flow type
Heat pipe
Heat pipe material
T2 copper
Heat pipe size
Top: Ø14* 1mm; Body: Ø8* 0.7mm
Tube diameter
φ47/1500mm or φ58/1800mm
Solar vaccum glass tube
High boron-silicon
Coating of absorber on glass tube
Al-N-Al,Copper,Stainless steel
fins around heat pipe
single long Aluminum(1.68m)
Manifold pipe material
TP2 copper (Ø35x0.8mm)
Manifold casing material
6063 Aluminum alloy frame(1.8mm)
Insulation material in manifold caseing
Glass fiber
Thickness of insulation(mm)
45
Density of insulation (kg/m3)
90
Frame material
6063 Aluminum alloy frame(3mm)
Frame and manifold casing finish
Black Powder coated
Sealing Materials
EPDM